ICT180S-12IRC Distribution Panel
IP Address: 209.121.192.80
Firmware: v2.09

Output Setup

Select an Output to edit   (Click "Save Settings" when finished)
#1: Radio 1#7: Repeater A
#2: Radio 2#8: Repeater B
#3: Radio 3#9: Repeater C
#4: Radio 4#10: Repeater D
#5: Radio 5#11: RF Amplifier
#6: Radio 6#12: Auxilary

Output # Settings
Output Label:
Output State after Panel Reset:
Ignore Fuse Status:
Enable Power Cycling:

If Power Cycling is enabled, "Sequence/Cycle Delay" must be set on the Device Setup page.

Output # Load-Shedding
Enable Load-Shedding:
Load-Shedding Threshold: VDC
Load-Shedding Auto Recovery:
Auto Recovery Threshold: VDC

If enabled, Load-Shedding will disable this output if the system voltage drops below the threshold for at least 30 seconds.

Output # Over-Current Alarm
Over-Current Threshold:> A

When an Over-Current condition occurs on this Output,
Activate Alarm Form C Contact:
Send E-mail:

This alarm will have no effect if the threshold is set to 0 Amps.

Output # Under-Current Alarm
Under-Current Threshold:< A

When an Under-Current condition occurs on this Output,
Activate Alarm Form C Contact:
Send E-mail:

This alarm will have no effect if the threshold is set to 0 Amps.